A clear strip that has gone yellow is the hardest complaint to answer. Two curtains can look identical in a photo and have completely different causes.
The colour comes from one of three places: heat history inside the material, the plasticiser breaking down, or light and chemicals attacking the surface. Each needs a different fix. Cleaning only helps the third.

Same doorway, same light.
Look at where the yellow sits
Hold it against a white sheet in daylight.
◆Even through the thickness. Cut an edge and check the cross-section. Colour through the thickness means degradation inside the compound or in processing. Cleaning will not touch it.
◆Edges and hanger line first. Start with the top 100 mm and the cut edges. That heat points, stress at the hanger, and metal contact.
◆Patchy, surface only. Brown blotches near a doorway or a hot appliance: cooking oil, smoke, rust, chlorine residue.
Cross section of clear PVC strip, yellowed through and surface only
Cause 1: heat history
Heated without enough stabiliser, PVC loses hydrogen chloride, creating conjugated double bonds that absorb light. That is why degraded PVC looks yellow long before it looks brown.
Four causes:
◆Compound mixed above 190 °C, or held hot too long.
◆Too much regrind. Regrind has already had one heat history.
◆Stabiliser level trimmed to save cost.
◆Hot spots on the screw or die, which yellow a band.
Permanent and uniform. Washing will not remove it.
Cause 2: plasticiser breakdown
Clear strip carries 30–50 phr of plasticiser, and the choice matters.
DEHA gives excellent low-temperature flexibility and clarity. It also volatilises and oxidises faster than DOTP. In a hot kitchen or a sunlit doorway, that shows up as a brown-yellow cast and a strip that stiffens.
Two signals: the strip feels harder than new, the surface tacky. Tacky means plasticiser came out. Hard means it has left.
Polymeric plasticisers resist this best. They cost more, and on a south-facing doorway the premium pays back.
Cause 3: light and chemicals
Ultraviolet light breaks the same bonds, more slowly. The sun-facing side yellows first, often alone.
Chemicals accelerate it. Hypochlorite and ammonia attack stabiliser and plasticiser. Cooking oil soaks in.
Metal contact is the one most people miss. Rust from a galvanised hanger or a stray steel screw stains the strip and catalyses degradation. If the yellow follows the fixings, suspect the metal first.

Rust travels from the fixing into the plastic.
Three checks that separate them
1. Cross-section.
Cut 20 mm off the bottom edge. Yellow through the thickness means heat or compound. Yellow on one face only means light.
2. White cloth and warm water.
Rub a small area. Brown on the cloth means deposit. No transfer and no change means the colour sits inside.
3. Two-week light test.
Cut two samples. Keep one in a drawer, tape one to the window. If only the window sample darkens, the cause is UV. Compare against a white card, or read the yellowness index.

Two weeks apart: drawer and window.
What site practice can still save
1. Wash with neutral detergent, pH 5 to 9, then rinse. Repeated hypochlorite yellows a clear strip fastest.
2. Keep water under 40 °C. Steam distorts strips and drives plasticiser out.
3. Store spares away from hot containers and sunlit walls. Above 40 °C, they age before use.
4. Replace rusted hangers. A stained fixing becomes a stained strip within a season.
5. Ventilate kitchens and washdown areas. Condensation plus cooking vapour ages any clear PVC.
What only the formulation can fix
If the yellow sits inside the material, cleaning cannot help. The fixes live in the recipe.
●Stabiliser system. Ca/Zn with 3–5 phr epoxidised soybean oil, plus a phosphite. Set the level for the heat history the line actually produces.
●Plasticiser. DOTP or a polymeric type where the strip meets heat and light. Keep DEHA for cold flexibility, where colour life matters less.
●Light stabilisers. A benzotriazole UV absorber at 0.2–0.5 phr and a HALS at 0.1–0.3 phr. Transparent grades need non-staining types, or the clarity you paid for disappears.
●Cleanliness. Iron and copper traces catalyse degradation. Rusty screws and worn barrels do more damage than most expect.
When cleaning will not help
Three cases where we tell customers to stop cleaning and change the spec.
Standard clear PVC is not an outdoor product. On a sunlit doorway in a high-UV region, expect yellowing within 12–24 months. Specify a UV-stabilised grade and budget 10–20% more.
A kitchen with daily frying oil and daily hypochlorite is the wrong home for standard clear. Accept a shorter life or move to a formulation built for the room.
Once yellowing runs through the thickness, replacement is the only answer. Cleaning spends labour and delivers nothing.
About the author
Written by the technical and export team at Baoding Yashen Technology Co., Ltd., Baoding, Hebei. Founded in 2013.
We make PVC curtain strips, PVC sheets, food-grade PVC wrap, phenolic rods, and the machinery that processes them, certified to CE, FDA, RoHS, and REACH, and shipped to more than 100 countries.
We supply the whole chain: raw material, machines, formulas. Yellowing complaints usually arrive with a photo and a batch number.
Send both, plus the room conditions. We will tell you which cause you are looking at.